- PRODUCTS
- Refurbish
- Promotions
- New
- Liquid Handling
- Laboratory Glassware
- Weighing accessories
- Volumetric instruments
- Tubes
- Thermometers
- Test tubes
- SVS-Combi-Boxes
- Storage vessels
- Stopper
- Stirring
- Staining vessels
- Staining jars
- ST-Combi-Boxes
- Spare parts
- Sample vessels
- Sample preparation
- Round bottom flasks
- Reaction vessels
- Racks
- Petri dish
- Parafilm
- Object holders & coverglasses
- Miscellaneous
- Life Science
- Insulating vessels
- Glass plates
- Funnels
- Flasks
- Filtration & separation
- Experimenting
- Distillation & extraction
- Dishes
- Desiccators
- Cuvettes
- Cultivation vessels
- Condensers
- Component parts
- van Slyke apparatuses
- Valves
- Stoppers
- Stopcocks
- Spherical joint
- socket members
- Socket
- Pourers
- Needle valves
- HV-flat flanges
- High vacuum needle valve stopcock
- Gas collectors
- Function-stop
- Flow controller
- Connection tubes
- Cones
- ball members
- Bag-stopcock acc. to Schiff
- Angled stopcock acc. to Schiff
- Angled high vacuum stopcock
- 3-way-high-vacuum-stopcock
- 3-arms-stopcock
- 2-arms-stopcock acc. to Schiff
- 2-arms-stopcock
- 1-arm-stopcock
- Columns
- Colorimetry
- Chromatography
- Bottles
- Beakers
- Accessories
- with Cone
- Transition pieces
- SVS-screw-thread
- Support
- Stoppers
- Standard Alu-caps
- Silicone gaskets
- Short adapter
- Screw thread coupling
- Screw caps
- Reduction adapter
- Quick release clamps
- quick release clamp
- plastic
- PE-stoppers
- O-rings
- Labocap-Closures
- Internal center rings
- Internal center ring
- Hose connection
- Hollow stopper
- hexagonal plate
- Flat flange
- Expansion adapter
- Cork laboratory rings
- Conical-spherical adapter
- Clips for joints
- Caps
- Capillary pipettes
- Blood sedimentation apparatuses
- Blood diluting tubes
- Laboratory Equipment
- Water Purification System
- UV/VIS Spectrophotometers
- Spectrocopy
- Safety & purification
- Pharmaceuticals Testing
- Mixing & shaking
- Miscellaneous
- Microbiological
- Heating
- Glasswar Washing
- Gas-Generator
- FTIR
- Filtration & separation
- Environment
- Cooling & freezing
- Chromatography
- Atomic Absorption Spectrometer
- Consumables
- Writing tools
- Weighing accessories
- Volumetric instruments
- Vial and cap
- Tubings
- Test tubes
- Syringes
- Storage vessels
- Spherical ground joint sleeves
- Sleeves for joints
- Silicone stoppers
- Sieves
- Sample vessels
- Sample preparation
- Reaction vessels
- Racks
- Protective clothing
- Protective & cleaning papers
- Plastic vessels
- pH Buffer capsules
- Parafilm
- Miscellaneous
- Micro titration plates
- Means
- Labels
- Indicator paper
- HPLC/GC Column
- gloves
- Funnels
- Foil-welding apparatus
- Flasks
- First aid equipment
- Filtration & separation
- Electrodes
- Dropping pipettes
- Cuvettes
- Cultivation vessels
- Cryo articles
- Crucibles
- Conductivity standard
- Combustions boats
- Cleaning concentrates
- Cleaning brushes
- Chromatography
- Centrifuging
- Casseroles
- Bottles
- Bellow
- Beakers
- Baskets
- Autoclave bags / Waste disposal bags
- Aluminium foil
- Acessories
- Accessories
- COMPANY
- NEWS
- EXHIBITIONS
- TRAINING AT CHEMTECH
- CONTACT
- DISTRIBUTION PARTNERS
- DOWNLOADS
GC-4100 Series Gas Chromatograph
Features
The GC-4100 Series is EWAI’s new generation of gas chromatographs. As compared with the GC-4000A Series, a number of technical improvements has resulted in better performance and greater automation. Up to ten gas paths can be controlled using EPC flow or pressure control, including the carrier gas, ignition gas, auxiliary gas, split flow and makeup gas, among others. Detector and column oven temperatures are controlled by a new and improved PID method, with a control accuracy of ± 0.03 ℃.
● The new TCD has less thermally conductive volume, which improves stability time. Our TCD is constructed with anti-oxidant components and features a constant average temperature bridge power supply to heat the filament. This results in an increase in sensitivity while improving lifetime. Using split flow injection with a capillary column and TCD, six consecutive analysis of benzene in toluene results in an RSD of less than 2.5%, as well as peaks with a small FWHM.
● The volume of the micro ECD cell has been reduced, resulting in greater baseline stability. Capillary columns can now be used with ECD. The sensitivity has been improved significantly. The detection limit now reaches 2 × 10-14 g/mL (γ-666).
Categories: Chromatography, Laboratory Equipment
Reviews (0)
Be the first to review “GC-4100 Series Gas Chromatograph” Cancel reply
Reviews
There are no reviews yet.